Product specification

product model

Maximum detection range

Detection accuracy

Scanning angle

output form

NJ501-1570CP

15m@70% reflectivity

±4mm@1sigma

270°

PNP

NJ501-1570CN

15m@70% reflectivity

±4mm@1sigma

270°

NPN

NJ501-2570CP

25m@70% reflectivity

±4mm@1sigma

270°

PNP

NJ501-2570CN

25m@70% reflectivity

±4mm@1sigma

270°

NPN

NJ501-2570HP

25m@70% reflectivity

±4mm@1sigma

270°

PNP

NJ501-2570HN

25m@70% reflectivity

±4mm@1sigma

270°

NPN

NJ501-3570HP

35m@70% reflectivity

±4mm@1sigma

270°

PNP

NJ501-3570HN

35m@70% reflectivity

±4mm@1sigma

270°

NPN

NJ501-4070HP

40m@70% reflectivity

±4mm@1sigma

270°

PNP

NJ501-4070HN

40m@70% reflectivity

±4mm@1sigma

270°

NPN

Installation mode

Horizontal installation mode (SZ), vertical installation mode (CZ) and protective cover installation mode (FZ)

Power cord

The standard is 1m, and the length of 5m can be selected.

Programming line

Standard gift

explain

The difference between NJ500 obstacle avoidance scanner C series and H series lies in:

1. The angular resolution of C series is: 0.3°@30HZ by default, and 0.3 @ 20/25/30hz/40hz is supported; The angular resolution of H series is: 0.3°@30HZ by default, and 0.3 @ 20/25/30hz/40/50hz is supported; In contrast, the H series has an extra 50Hz motor speed.

2. The response time of H series can be faster by scanning the same data.

3. At the same time, the display refresh rate of objects around H series is higher.


Laser scanner main body

 Power cordProgramming line

1726194842215581.png

 

1667524189836556.png


96160.png


technical parameter

Angular resolution

Measuring parameter

Ranging radius

15m@70% reflectivity /25m@70% reflectivity /35m@70% reflectivity /40m@70% reflectivity

Scanning range angle

270°

Angular resolution

The default value is 0.3°@30HZ, and it supports 0.3 @ 20/25/30hz/40Hz/50Hz (NJ 500 obstacle avoidance scanner C series supports 40hz at the highest and H series supports 50hz at the highest).

Distance deviation

±2cm(Typical) ①

repeatability

±4mm@1sigma②

Scanning plane angle

Pitch 0.5; Roll 0.5

Electrical/mechanical parameters

operating voltage

DC9~28V

Power-on start time

Typical value 10s

power consumption

< 2w (no load at output)

output

PNP/NPN available (default PNP)

outline dimension

52mm×52mm×70mm

Cable length

standard 1m

ambient temperature

Work:-10℃ ~ 50℃ (no frost and fog in the window); Storage:-40℃ ~ 70℃

ambient humidity

Work: 35% RH ~ 85% RH; Storage: 35% RH ~ 95% RH

Anti-light interference

80000Lux

resist the impact

Acceleration 10g;; Pulse duration: 16ms

Collision times: three axes, each axis is 1000 10 times.

Vibration resistance

Frequency 10 Hz ~ 55 Hz; Amplitude: 0.35±0.05mm

Scanning times: 20 times for each of XYZ three axes.

the protection grades

IP65

Electromagnetic compatibility

(EMC)

EMI

EN61326-1:2013

EN55011:2009+A1:2010

EMS

EN61326-1:2013

EN61000-4-2:2009

EN61000-4-3:2006+A1:2009+A2:2010

EN61000-4-4:2004+A1:2010

EN61000-4-6:2014

EN61000-4-8:2010

Configurable function

Sector configuration

Users can configure YB's protection zone into the required shape through configuration software.

Response time

67ms(2 scans) ~ ~536ms(16 scans), and the default is 67ms.

Zone group switching

Four groups of external input signals (INPUT1, INPUT2, INPUT3, INPUT4) realize the switching of 16 regional groups.

Note:

1. The measurement error of materials with different reflectivity is controlled within 2cm (typical value). The ex-factory test method: Three kinds of test pieces (black flannel, white paper and reflective sticker) are placed at different angles and the same distance (59cm) on the whole machine inspection automation fixture. The deviation between the central value of each material and the real distance is within 2 cm, and the maximum difference between the three materials is within 2 cm.

2. 10% black velvet 600mm position measurement statistics.


Schematic diagram of working principle and protection area configuration

Schematic diagram of protection area 1

Schematic diagram of protection area 2

1726196477634861.png1726196505964341.png

sign

meaning

describe

1

Protected area 1

OUTPUT1 enters the OFF state when an obstacle is detected.

2

Protected area 2

OUTPUT2 enters the OFF state when an obstacle is detected.

3

Protected area 3

OUTPUT3 enters the OFF state when an obstacle is detected.

Note:

1. The measurement error of materials with different reflectivity is controlled within 2cm (typical value). The ex-factory test method: Three kinds of test pieces (black flannel, white paper and reflective sticker) are placed at different angles and the same distance (59cm) on the whole machine inspection automation fixture. The deviation between the central value of each material and the real distance is within 2 cm, and the maximum difference between the three materials is within 2 cm.

2. 10% black velvet 600mm position measurement statistics.



Schematic diagram of working principle and protection area configuration

Schematic diagram of protection area 1

Schematic diagram of protection area 2

1726196477634861.png1726196505964341.png

sign

meaning

describe

1

Protected area 1

OUTPUT1 enters the OFF state when an obstacle is detected.

2

Protected area 2

OUTPUT2 enters the OFF state when an obstacle is detected.

3

Protected area 3

OUTPUT3 enters the OFF state when an obstacle is detected.


Indicator light status

1726196717891121.png

OK: After power-on, the trouble-free OK light is always on, and the trouble-free OK light flashes.

INPUT(1~4): lit when the input is ON, and turned OFF when the input is OFF.

OUTPUT(1~3): lights when there is no obstacle, and turns off when there is an obstacle.

Note: When the equipment is just powered on, all the indicator lights will enter the running water state, and the OK light will go out for 10 seconds, indicating that the equipment is starting and is in a normal state.


Cable interface

The configuration cable is a standard USB Type-C data cable (optional).

See the figure below for the cable structure, and the standard cable length is 1m.

1726196848500139.png

colour

signal

describe

blue

0V

working power supply

palm

24V

Yellow/green

PE

Red/blue

COM

The common terminal of the regional group switching signal input, when the input signal is PNP logic, COM is connected to 0V; When the input signal is NPN logic, COM is connected to 24V.

powder

INPUT1

Regional group selection signal, which can switch between regional groups through the changes of input signals of INPUT1, INPUT2, INPUT3 and INPUT4.

green

INPUT2

ash

INPUT3

red

INPUT4

black

OUTPUT1

Three independent PNP(NPN) outputs;

PNP transistor output; In the ON state, the load current is ≤100mA and the output voltage is ≥ VCC-2v; In the OFF state, the leakage current is ≤1mA, and the residual voltage is ≤ 1V (excluding the influence of wire extension).

When the NPN transistor outputs, the load current is ≤100mA and the output voltage is ≤2V in the ON state; In the OFF state, the leakage current is ≤1mA and the residual voltage is ≤2V (excluding the influence of wire extension).

The protectiON area is on when there is no object; In the OFF state when there is an object.

white

OUTPUT2

purple

OUTPUT3

Ash/powder

OK

Independent PNP(NPN) output, the fault state output is OFF, and it is ON when there is no fault.


Product dimension diagram

1726197437255476.png


Scanning range

1726197507946675.png


Installation mode

Horizontal installation mode

1726197845421148.png      1726197877884073.png

Vertical installation mode

1726197965435752.png1726198002661049.png

Installation mode of protective cover

1726198028335499.png1726198054130018.png
Related Products
Download
PDF file download
Video file download
Previous

Contact us

400-881-6062

Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

E-Mail: info@lh-safety.com

Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

(Greenland East Coast International Plaza-Room A 313)

Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

Online service

Online message

  • Click to refresh
  • 主站蜘蛛池模板: 国产黄大片在线观看| 国产免费无码一区二区视频| 草草久久久无码国产专区| 国产精品午夜小视频观看| 欧美精品黑人粗大| 亚洲精品国产精品国自产观看| 国产熟女内射oooo| 亚洲 欧美 综合 另类 中字| 亚洲人成无码网站在线观看| 麻豆文化传媒精品一区二区| 99久久人妻精品免费二区| 麻豆一区二区在我观看 | 亚洲国产精品综合久久网各| 国产第一页屁屁影院| 国产又爽又粗又猛的视频| 太粗太深了太紧太爽了动态图男男| 国产精品卡一卡二卡三| 97人妻精品一区二区三区| 亚洲欧美色一区二区三区| 国产成人精品日本亚洲11| 精品久久久久久国产潘金莲| 爆乳一丝丝不挂裸体大胸美女写真 | 精品乱人伦一区二区三区| 门国产乱子视频观看| 亚洲av片不卡无码久久| 欧美性群另类交| 久久久99精品免费观看| 成人毛片无码一区二区三区| 免费无码av片在线观看| 欧美性猛交xxxxx按摩欧美 | 国产成人无码av一区二区在线观看| 对白脏话肉麻粗话av| 欧美大成色www永久网站婷| 国内少妇偷人精品视频免费| 精品久久久久久久久中文字幕| 情侣黄网站免费看| 男女裸交无遮挡啪啪激情试看| 美女露出奶头扒开尿口免费网站| 国产md视频一区二区三区| 在线观看亚洲av每日更新| 亚洲精品无码久久久|