日本e片色视频-亚洲国产精品无码一区二区三区-国产99视频精品免费视频76-中文字幕在线精品视频入口一区-欧美疯狂性受xxxxx喷水

Welcome to the official website of Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.!
Position首頁 > Home > Safety products > sensor傳感器 > Area scanner
NJ500 series obstacle avoidance laser scanner


1726194842215581.png

·It is a single-line lidar based on dTOF ranging principle.

·It has the advantages of small size, simple use and high cost performance.

·Suitable for navigation, obstacle avoidance and diversification of regional monitoring scenes.


Product specification

product model

Maximum detection range

Detection accuracy

Scanning angle

output form

NJ501-1570CP

15m@70% reflectivity

±4mm@1sigma

270°

PNP

NJ501-1570CN

15m@70% reflectivity

±4mm@1sigma

270°

NPN

NJ501-2570CP

25m@70% reflectivity

±4mm@1sigma

270°

PNP

NJ501-2570CN

25m@70% reflectivity

±4mm@1sigma

270°

NPN

NJ501-2570HP

25m@70% reflectivity

±4mm@1sigma

270°

PNP

NJ501-2570HN

25m@70% reflectivity

±4mm@1sigma

270°

NPN

NJ501-3570HP

35m@70% reflectivity

±4mm@1sigma

270°

PNP

NJ501-3570HN

35m@70% reflectivity

±4mm@1sigma

270°

NPN

NJ501-4070HP

40m@70% reflectivity

±4mm@1sigma

270°

PNP

NJ501-4070HN

40m@70% reflectivity

±4mm@1sigma

270°

NPN

Installation mode

Horizontal installation mode (SZ), vertical installation mode (CZ) and protective cover installation mode (FZ)

Power cord

The standard is 1m, and the length of 5m can be selected.

Programming line

Standard gift

explain

The difference between NJ500 obstacle avoidance scanner C series and H series lies in:

1. The angular resolution of C series is: 0.3°@30HZ by default, and 0.3 @ 20/25/30hz/40hz is supported; The angular resolution of H series is: 0.3°@30HZ by default, and 0.3 @ 20/25/30hz/40/50hz is supported; In contrast, the H series has an extra 50Hz motor speed.

2. The response time of H series can be faster by scanning the same data.

3. At the same time, the display refresh rate of objects around H series is higher.


Laser scanner main body

 Power cordProgramming line

1726194842215581.png

 

1667524189836556.png


96160.png


technical parameter

Angular resolution

Measuring parameter

Ranging radius

15m@70% reflectivity /25m@70% reflectivity /35m@70% reflectivity /40m@70% reflectivity

Scanning range angle

270°

Angular resolution

The default value is 0.3°@30HZ, and it supports 0.3 @ 20/25/30hz/40Hz/50Hz (NJ 500 obstacle avoidance scanner C series supports 40hz at the highest and H series supports 50hz at the highest).

Distance deviation

±2cm(Typical) ①

repeatability

±4mm@1sigma②

Scanning plane angle

Pitch 0.5; Roll 0.5

Electrical/mechanical parameters

operating voltage

DC9~28V

Power-on start time

Typical value 10s

power consumption

< 2w (no load at output)

output

PNP/NPN available (default PNP)

outline dimension

52mm×52mm×70mm

Cable length

standard 1m

ambient temperature

Work:-10℃ ~ 50℃ (no frost and fog in the window); Storage:-40℃ ~ 70℃

ambient humidity

Work: 35% RH ~ 85% RH; Storage: 35% RH ~ 95% RH

Anti-light interference

80000Lux

resist the impact

Acceleration 10g;; Pulse duration: 16ms

Collision times: three axes, each axis is 1000 10 times.

Vibration resistance

Frequency 10 Hz ~ 55 Hz; Amplitude: 0.35±0.05mm

Scanning times: 20 times for each of XYZ three axes.

the protection grades

IP65

Electromagnetic compatibility

(EMC)

EMI

EN61326-1:2013

EN55011:2009+A1:2010

EMS

EN61326-1:2013

EN61000-4-2:2009

EN61000-4-3:2006+A1:2009+A2:2010

EN61000-4-4:2004+A1:2010

EN61000-4-6:2014

EN61000-4-8:2010

Configurable function

Sector configuration

Users can configure YB's protection zone into the required shape through configuration software.

Response time

67ms(2 scans) ~ ~536ms(16 scans), and the default is 67ms.

Zone group switching

Four groups of external input signals (INPUT1, INPUT2, INPUT3, INPUT4) realize the switching of 16 regional groups.

Note:

1. The measurement error of materials with different reflectivity is controlled within 2cm (typical value). The ex-factory test method: Three kinds of test pieces (black flannel, white paper and reflective sticker) are placed at different angles and the same distance (59cm) on the whole machine inspection automation fixture. The deviation between the central value of each material and the real distance is within 2 cm, and the maximum difference between the three materials is within 2 cm.

2. 10% black velvet 600mm position measurement statistics.


Schematic diagram of working principle and protection area configuration

Schematic diagram of protection area 1

Schematic diagram of protection area 2

1726196477634861.png1726196505964341.png

sign

meaning

describe

1

Protected area 1

OUTPUT1 enters the OFF state when an obstacle is detected.

2

Protected area 2

OUTPUT2 enters the OFF state when an obstacle is detected.

3

Protected area 3

OUTPUT3 enters the OFF state when an obstacle is detected.

Note:

1. The measurement error of materials with different reflectivity is controlled within 2cm (typical value). The ex-factory test method: Three kinds of test pieces (black flannel, white paper and reflective sticker) are placed at different angles and the same distance (59cm) on the whole machine inspection automation fixture. The deviation between the central value of each material and the real distance is within 2 cm, and the maximum difference between the three materials is within 2 cm.

2. 10% black velvet 600mm position measurement statistics.



Schematic diagram of working principle and protection area configuration

Schematic diagram of protection area 1

Schematic diagram of protection area 2

1726196477634861.png1726196505964341.png

sign

meaning

describe

1

Protected area 1

OUTPUT1 enters the OFF state when an obstacle is detected.

2

Protected area 2

OUTPUT2 enters the OFF state when an obstacle is detected.

3

Protected area 3

OUTPUT3 enters the OFF state when an obstacle is detected.


Indicator light status

1726196717891121.png

OK: After power-on, the trouble-free OK light is always on, and the trouble-free OK light flashes.

INPUT(1~4): lit when the input is ON, and turned OFF when the input is OFF.

OUTPUT(1~3): lights when there is no obstacle, and turns off when there is an obstacle.

Note: When the equipment is just powered on, all the indicator lights will enter the running water state, and the OK light will go out for 10 seconds, indicating that the equipment is starting and is in a normal state.


Cable interface

The configuration cable is a standard USB Type-C data cable (optional).

See the figure below for the cable structure, and the standard cable length is 1m.

1726196848500139.png

colour

signal

describe

blue

0V

working power supply

palm

24V

Yellow/green

PE

Red/blue

COM

The common terminal of the regional group switching signal input, when the input signal is PNP logic, COM is connected to 0V; When the input signal is NPN logic, COM is connected to 24V.

powder

INPUT1

Regional group selection signal, which can switch between regional groups through the changes of input signals of INPUT1, INPUT2, INPUT3 and INPUT4.

green

INPUT2

ash

INPUT3

red

INPUT4

black

OUTPUT1

Three independent PNP(NPN) outputs;

PNP transistor output; In the ON state, the load current is ≤100mA and the output voltage is ≥ VCC-2v; In the OFF state, the leakage current is ≤1mA, and the residual voltage is ≤ 1V (excluding the influence of wire extension).

When the NPN transistor outputs, the load current is ≤100mA and the output voltage is ≤2V in the ON state; In the OFF state, the leakage current is ≤1mA and the residual voltage is ≤2V (excluding the influence of wire extension).

The protectiON area is on when there is no object; In the OFF state when there is an object.

white

OUTPUT2

purple

OUTPUT3

Ash/powder

OK

Independent PNP(NPN) output, the fault state output is OFF, and it is ON when there is no fault.


Product dimension diagram

1726197437255476.png


Scanning range

1726197507946675.png


Installation mode

Horizontal installation mode

1726197845421148.png      1726197877884073.png

Vertical installation mode

1726197965435752.png1726198002661049.png

Installation mode of protective cover

1726198028335499.png1726198054130018.png
Related Products
Download
PDF file download
Video file download
Previous

Contact us

400-881-6062

Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

E-Mail: info@lh-safety.com

Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

(Greenland East Coast International Plaza-Room A 313)

Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

Online service

Online message

  • Click to refresh
  • 主站蜘蛛池模板: 久久人人爽人人人人片av| 全免费a级毛片| 久久午夜伦鲁片免费无码| 国产v综合v亚洲欧美久久 | 麻豆av一区二区三区久久| 国模小黎自慰gogo人体| 亚洲午夜精品久久久久久app| 四川丰满妇女毛片四川话| 男生女生在床上插插插的免费动漫| 两性午夜刺激性视频| av无码av无码专区| 男女做爽爽爽网站| 少妇高潮太爽了在线视频| 欧美人妻aⅴ中文字幕| 亚洲热线99精品视频| 最新国产av无码专区亚洲| 亚洲午夜久久久久妓女影院| 99精品久久久久久久婷婷| 国产精品久久毛片| 国产一极内射視颍一| 亚洲s码欧洲m码吹潮| а天堂中文在线官网在线| 国产女人被狂躁到高潮小说| 女人被狂c到高潮视频网站| 亚洲av无码成人精品区| 日本一区二区三区免费播放| 亚洲欧洲免费无码| 老色鬼永久精品网站| 特黄aaaaaaaaa毛片免费视频| 国产成人无码a区在线观看导航| 成年女人免费v片| 欧美日韩精品久久久久| 国内偷窥一区二区三区视频| 无码av免费一区二区三区| 欧美日韩人妻精品一区二区三区 | 国产99视频精品免费专区| 久久亚洲春色中文字幕久久久| 女人夜夜春高潮爽a∨片| 99精品国产丝袜在线拍国语| 色婷婷日日躁夜夜躁| 精品久久人妻av中文字幕|